What was found
FIVE MIN AFTER L ENG BLEED MESS R ENG OVERHEAT CAME ON (BOTH ENG OVERHEAT & EICAS MESSAGE) QRH ACCOMPLISH STARTED APU & TURN R BLEED OFF REF L/P 8884944 & L/P 8886900 FOR CORRECTIVE ACTION PERFORMED HIGH POWER ENG RUNS REF AMM 71-00-00. NO DEFECTS NOTED AT THIS TIME - PERFORMED FIM TASK 36-10-00-815-811 R&R 450 TEMP SENSOR REF AMM 36-11-13 PERFORMED HIGH POWER ENG RUNS REF AMM 71-00-00 NO DEFECTS NOTED AT THIS TIME.