What was found
CABIN - STA 986.5 RBL 27 - RBL 44 FLOOR SUPPORT CORRODED. CABIN STA 986.5 RBL 27 TO RBL 44 FLOORBEAM OF UPPER SURFACE COR REMOVED AND BLENDED AREA D=0.050" (ORG 0.155") X W=0.8" X L=3" OUT OF SRM 53-70-51 ALLOWABLE DAMAGE 1 FIG 103 LIMITS AND FLOORBEAM CORRODED AREA REPAIRED AS PER ECRA 5321-01429 C REPAIR B DETAILS AND FORM 44.0008 ITEM 1-26 ACCOMPLISHED.