What was found
FIRE PANEL FAULT LIGHT CAME ON DURING FLIGHT AND THEN WENT OUT. LIGHT CAME BACK ON AND NOW INDICATES "A" LOOP FAILURE ON NR 2 ENG. CONFIRMED NR 4 AFT LOOP A AND B TERM FAULTS. WIRES GENTLY PULLED FROM TERM BARREL. REPLACED THREE TERMINAL ENDS IAW AMM 26-11-02. WIRE SUFFICIANT LENGTH IAW FIG 808. SECURED AND TESTED AS ADVERTISED. OPS OK. COWL SECURED CLOSED. OK FOR SVC.