What was found
AILERON LOCK LIGHT ON AT HIGH SPEED. EICAS MESSAGE AILERON LOCKOUT DISPLAYED. OTBD AILERONS INDICATED NORMAL, LOCKED OUT. ACCOMPLISH CHRONIC REVIEW. REPLACED RT AILERON LOCKOUT ACTUATOR IAW AMM, TEST PASSED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AILERON LOCK LIGHT ON AT HIGH SPEED. EICAS MESSAGE AILERON LOCKOUT DISPLAYED. OTBD AILERONS INDICATED NORMAL, LOCKED OUT. ACCOMPLISH CHRONIC REVIEW. REPLACED RT AILERON LOCKOUT ACTUATOR IAW AMM, TEST PASSED.