What was found
DURING DESCENT, WHILE USING SPOILERS, SPOILER EICAS ILLUMINATED. ALSO SPOILER FAULT WHEN SPOILER STOWED. ACCOMPLISHED RESISTANCE CHECK REF FIM 27-09-806, PAGE 126 ON SPOILERS NR 3 AND NR 10, NR 3-PIN 1 & 3, 519.9, PIN 8 & 9, 78.3, PIN 5 & 7, 342.4. FOUND WITHIN LIMITS NR 10-PIN 1 & 3, 501.4 PIN 8 & 9, 78.5 PIN 5 & 7, 338.7. FOUND 10379 WITHIN LIMITS. REPLACED 2R SCM 27-09-00, CHECKED OK, OPS NORMAL WITH NO FAULTS OR MESSAGES.