What was found
LGCIU 2 SYSTEM FAULT MESSAGE. R & R LT MLG 2M HARNESS ASSEMBLY PN 201400005. IAW AMM 32-11-43-000-001A & -400-002A . PERFORMED OPERATIONS CHECKED CALLED OUT FOR IN AMM. ALL FAULTS CLEARED & LGCIU'S OPERATIONS CHECKED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LGCIU 2 SYSTEM FAULT MESSAGE. R & R LT MLG 2M HARNESS ASSEMBLY PN 201400005. IAW AMM 32-11-43-000-001A & -400-002A . PERFORMED OPERATIONS CHECKED CALLED OUT FOR IN AMM. ALL FAULTS CLEARED & LGCIU'S OPERATIONS CHECKED NORMAL.