What was found
ENG 1 START FAULT ECAM ENG 1 EGT OVERLIMIT BUT DIDN'T SHOW OVERHEAT ON GAUGE HIGHEST 535. REPLACED 7TH & 10TH STAGE SOLENOID VALVES IAW MM, OPERATIONS CHECKED GOOD. THREE NORMAL STARTS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ENG 1 START FAULT ECAM ENG 1 EGT OVERLIMIT BUT DIDN'T SHOW OVERHEAT ON GAUGE HIGHEST 535. REPLACED 7TH & 10TH STAGE SOLENOID VALVES IAW MM, OPERATIONS CHECKED GOOD. THREE NORMAL STARTS.