What was found
ENTERTAINMENT SYSTEM STILL HAS PROBLEMS, BURNT TERMINAL. DEBRIEFED CREW WAS TOLD FC IFE WORKED INTO ORD. WHEN INVESTIGATED FOUND FC IFE ALL POWER INOPERATIVE. AMCU NR 1 FAULT RED LRU LED LIGHT ON. ALL CB ON P210 & P-110 ASSOCIATED IN. FOUND AMCU NR 1 CB ON P110 PANEL PULLED. AFTER RESETTING CB ALL FC IFE FUNCTIONS OPERATIONS CHECKED OK. PERFORMED POWER SWAPS , STRESS TESTS & BITE. ALL OPERATIONS CHECKED NORMAL. REPLACED CB C23307 IN P110 PNL, IAW WDM 23-32-32 REPLACED CONN ON WIRE W3113-0228-16 AT CB C23307 IAW GPM 02-0-21-001 & SWP 20-30-11 DUE TO BURNT TERMINAL. OPERATIONS CHECKED NORMAL NO FAULTS.