What was found
LGCIU 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. LG CLEANED CONNECTOR ON NOSE GEAR PROX SENSOR 24GA & ACCOMPLISHED LGCIU 1 TEST, ALL OKAY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LGCIU 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. LG CLEANED CONNECTOR ON NOSE GEAR PROX SENSOR 24GA & ACCOMPLISHED LGCIU 1 TEST, ALL OKAY.