As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN STATION 3328 RBL 11 - 30 FLOORBEAM FOUND CORROSION, TOTAL FOUR EACH. REM IAW SRM 51-10-02 BLEND OUT AREA D0.78" ORG THK0.130" X W1"XL3" OUT OF SRM 53-10-51. ALLOWABLE DMG 1 FIG 105 LIMIT & FLOORBEAM CORROSION REM AREA REPAIRED IAW SRM53-10-51. REPAIR 7 FIG 205 & INTERCOSTAL CLIP PN 141A576 2-2 REPLACED & NEW CLIP INSTALLED IAW ECRA 5310-06107 REV.