What was found
CRACK INDICATION FOUND AT FASTENER HOLES COMMON TO SEAT TRACK OTBD & INBD FLANGES LOCATED AT FWD STATION 727B RBL 45.50. TRIMMED CRACKED AREAS, FABRICATED REPAIR SPLICE, MATERIAL USED 7075T6 0.125 INCHES, REPAIR FILLER NR 1 MATERIAL 7075T6 0.090 INCHES, REPAIR FILLER NR 2 MATERIAL USED 7075T6 0.160 INCHES. TREATED, PRIMED & INSTALLED IAW RES NR 2007476-17.