What was found
FLAP INDICATION STUCK AT 5 WITH 15, THEN 30 COMMANDED BY FLAP LEVER, WENT AROUND, WENT TO FLAPS TEF DISAGREE CHECKLIST. SET FLAPS 2, INDICATOR WENT TO 2, SET FLAPS 5, THEN 10. FLAPS TRACKED NORMALLY & INDICATED 5,10. THEN SET FLAPS 30, INDICATED 30, LANDED NORMALLY. ACCOMPLISHED FSEU BITE & FAULT HISTORY REVIEW. BITE NORMAL, NO FAULTS. VISUALLY INSPECTED FLAPS AT 0 & 40, NO DEFECTS NOTED. OPERATIONAL TEST OF FLAPS WITH PRIMARY CONTROL NORMAL IAW FIM 27-51-00-81 0-836.