What was found
LOSS OF ELEC ESSENTIAL POWER BUSS ON CLIMB OUT. REPLACED 15XE CONTACTOR IAW WD 24-24-06 AS PRECAUTION IAW AMM 24-24-55-401. WIRES CHECKED IAW TSM 24-50-00-810-814-A & BOTH 15XC ,16XC RELAYS REPLACED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LOSS OF ELEC ESSENTIAL POWER BUSS ON CLIMB OUT. REPLACED 15XE CONTACTOR IAW WD 24-24-06 AS PRECAUTION IAW AMM 24-24-55-401. WIRES CHECKED IAW TSM 24-50-00-810-814-A & BOTH 15XC ,16XC RELAYS REPLACED.