As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STRINGER 40R, JUST AFT OF STATION 2344, FOUND CORRODED ALONG WITH THE SKIN, BETWEEN STATION 2344 & 2370 & BETWEEN STRINGERS 40R & 43R. BOTH AREAS REPAIRED IAW ECRA 5310-06617. REPEAT INSPECTIONS NEED TO BE ACCOMPLISHED IAW PART 2 OF ECRA AT INTERVALS NOT TO EXCEED 750 DAYS. ACCOMPLISH REPEAT INSPECTIONS IAW ECRA 5310-06617 PART 2 AT INTERVALS NOT TO EXCEED 750 DAYS.