What was found
DENT AT FUSELAGE STATION 640, BETWEEN STRINGER 17L - 18L, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01 AD1 FIG.101 DETAIL III. REPAIRED FUSELAGE SKIN AT STATION 640, BETWEEN STRINGER 17L - 18L IAW SRM 53-00-01 REPAIR 3 FIG 201. THIS IS CATEGORY B REPAIR WITH REPETITIVE INSPECTION IAW SRM 53-00-01 REPAIR 3 FIG 201 PAGE 207 TABLE V.