What was found
FUSELAGE SKIN DENTED STATION 199 - 205, STRINGER 22R - 23R. REPAIR INITIAL INSPECTION IS AT 37,500 AIRFRAME CYCLES & REPEAT HFEC EVERY 3K FLT CYCLES & HFEC EVERY 6K FLT CYCLES. INSTALLED REPAIR DOUBLER & NEW CLIPS IAW SRM 53-00-07 REPAIR 5 FIG 201 DETAIL II. INITIAL INSPECT BEFORE 37,500 TOTAL CYCLES & REPEAT LFEC INSPECTION EVERY 3000 CYCLES & HFEC INSPECTION EVERY 6000 CYCLES THEREAFTER IAW SRM 53-00-01 REPAIR 3. .