What was found
SLAT NR 9 HAS CRACKED LOWER SKIN AT MIDDLE OF SLAT CRACK. TRIMED OUT DAMAGE PER SRM 57-43-01 REPAIR 5 FOUND 2 ELONGATED FATENERS HOLES COMMON TO REPAIR ON O/B REF AVO 001030JUN16-1 SLAT. CLEANED OUT FASTENER HOLES SEE L/P 3184312 FOR FREEZE PLUG MATERIAL VERIFICATION. DEFLECTION CONTROL RIB. FINAL DIMENSION AFTER CLEAN OUT OF WEDGE SKIN AND RIB. .410 DIA. PROVIED SKECTCH TO ESC. FABRICATED AND INSTALLED FREEZE PLUG IAW AVO 001030JUN16-2 SLAT. AND SRM 51-20-07.