What was found
EICAS MESSAGE FOR TE FLAP DISAGREE DISPLAYED, TRAILING EDGE LIGHT ILLUMINATED, WHEN ANY TE FLAP POSITION SELECTED. FLAPS FAIL TO MOVE TO SELECTED POSITION. TE FLAP DISAGREE ROTARY ACTUATOR REMOVED AND REPLACED IAW AMM 27-51-32. ACCOMPLISHED TE PDU TEST, ALL OPS AND INDICATIONS NORMAL. FS EU TEST-OK, NO FAULTS. FLAPS-SLATS RUN THRU FULL CYCLE, OK.