As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MOMENTARY N2 OVSPD NO 1 ENG DURING MAX EPR TAKEOFF. R&R LEFT SOLENOID ON NR 1 ENG IN REF TO AMM75-32-03-404 015-R04. REMOVED AND REPLACED RIGHT SOLENOID VALVE ON LEFT ENGINE IAW AMM 75-32-03-404-046-R04. PER FIM TASK 75-32-00-815-824-R06 ACCOMPLISHED RESISTANCE CHECK OF D1364, D1362, D1484, D1388 AND EVERYTHING IS WITHIN LIMITS PER FIM. PERFORMED TEST 3 AND BVCU TEST PER REMOVAL AND INSTALLATION OF IP BLEED VALVES IAW 75-32-03. OPS CK GOOD.