What was found
CORROSION FOUND ON AFT WET AREA WEB BS 1706, LBL 5. REMOVED CORROSION IAW AMM 51-00-53, FOUND AREA OUT OF LIMITS AND FOUND A HOLE CRACKED, OVERSIZE HOLE IAW EC/RA 53330/04259, STEP 3, II. FABRICATED A DOUBLER REPAIR, LOCATED, DRILLED, TREATED AND PRIMED AND INSTALLED IAW EC/RA 5330-04259