As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO UNDER FLOOR AREA HAS SURFACE CORROSION ON THE SHEAR TIE LOCATED ON FRAME 29 BETWEEN STRINGERS 43-44R. EVALUATED AND REMOVED CORROSION FRO M CLEAT MATERIAL REMOVED WAS NOT WITHIN LIMITS IAW NSA2110. REPLACED SHEAR TIE WITH NEW CLEAT IAW SRM 51-72-11-911-001, AND SRM 51-42-11-001