What was found
AFT CARGO UNDER FLOOR AREA, FLOOR SUPPORT BRACKETS LOCATED ON TOP OF FR59 BETWEEN STR41R-38L HAS SPOTS OF UPPER SURFACE CORROSION AND DOUBLE DRILLED HOLE. BLEND CORROSION AT FR59 STR41R-38L SUPPORT BRACKET FOUND TO BE O UT OF LIMITS, ALSO DOUBLE DRILL HOLE IAW A319 DAN 11304, RECEIVED CROSSBEAM AND ANGLE AND INSTALLED IAW A319 SRM 51-72-11-911-00 1