What was found
STATUS MESSAGE FOR THE LT STRUT OVERHEAT DETECTOR 1. EMERGENCY DECLARED. REPLACED PRSOV IAW AMM 36-11-09. FOUND PNEU FITTING ON VALVE GALLED. NO LEAKS NOTED WITH DUCTS PRESSURIZED IAW AMM 36-11-09, ACCOMPLISHED ENGINE RUNS 80 PERCENT N1, 10 MINUTES, NO STATUS MESSAGES DISPLAYED, PRSOV OPS NORMAL.