What was found
REF TO AAR NON ROUTINE 9611821 (ESR #8) R/H WINDSHIELD FR 4 SIDE POST AFT LOWER WEB HAS A CRACK INDICATION. ECRA AND DIP DEFERRAL ARE TO CLOSE EXISTING C-CHECK PACKAGE AND RE-OPEN AS STAND ALONE EVENT, NO FLIGHT ALLOWED RE-POSITION A/C FOR A STAND ALONE CHECK TO ACCOMPLISH REPLACEMENT OF R/H LATERAL WINDSHIELD FRAME WITHIN 1 DAY. AT AAR DLH. NO FLIGHTS OF ANY TYPE ARE PERMITTED. SEE PART 3 OF ECRA 5311-02038 FOR PERMANENT REPAIR INSTRUCTIONS. REF ECRA 5311-02038 -REPOSITION AIRCRAFT FOR STAND-ALONE CHECK TO ACCOMPLISH REPLACE WINDSHIELD FRAME WITHIN ONE (1) DAY. NO FLIGHTS OF ANY TYPE ARE OF EC/RA 5311-02038 FOR PERMANENT REPAIR INSTRUCTIONS.- TOMC-APPROVAL FROM SC1ELBYC COMMENT TOMC APPROVED : QC REVIEWED TOMC APPROVED : QC REVIEWED RECORDS UPDATE T/A: 1 DAY.....LT/U224600 REPLACED RH LATERAL WINDOW FRAME PER EC/RA 5311-02044 ACCOMPLISH INSPECTION REQUIREMENTS PER PART 2 OF EC/RA 5311-02044 ON OR BE FORE THE A/C REACHING 66,607 TOT A/C FLIGHT CYCLES. PLANNING TO CONTACT ENGINNEERING AFTER 64,607 TOT.FC . BUT BEFORE 65,607 TOT AL FC FOR THE INSPECTION REQUIREMENTS FH NOT RELAVENT INTERVALS TBD METHOD TBD REF LOG 8312029 . REF TO AAR N/R 9611821. AND LOG PAGE 8312029. INSPECTION COMPLIED WITH. TOMCQC REV PERFORMED