What was found
ROTO PROBE INSPECTION OF DOUBLE JOGGLE SHOW S CRACK INDICATION AT DOOR STOP #7 LOCATION (UPPER LOCATION) LH SIDE, 4TH FASTENER OF AFT COLUMN INTERIM REPAIR PERFORMED PER PART 1 OF ECRA 5311-02127. *DIP CREATED* THEREAFTER INTERIM REPAIR PERFORMED PER PART 1 OF ECRA 5311-02127. ACCOMPLISH THE INITIAL INSPECTION REQUIREMENTS AT LH FR20 DOOR STOP FITTING #7 PER PART 2 OF ECRA 5311-02127 ON OR BEFORE THE AIRCRAFT REACHES 33,706 TOTAL AIRCRAFT FLIGHT CYCLES. ACCOMPLISH THE REPEAT INSPECTIONS AT INTERVALS NOT TO EXCEED 5,910 AIRCRAFT FLIGHT CYCLES THERE AFTER. PART 1 REPAIR IS CONSIDERED PERMANENT PROVIDED PART 2 RECHECKS ARE COMPLIED WITH. TOMC-APPROVAL FROM SC1ELBYC COMMENT QC REVIEWED QC REVIEWED RECORDS UPDATE INIT: 33,706 TAFC; AUTO-ITO TO RIR(-2049) RIR: 5,910 F/C.....DH