What was found
DOOR-MOUNTED ESCAPE SYSTEM DOOR 2L - A EVACUATION SLIDE PROBLEM WAS ENCOUNTERED WHICH IS NOT COVERED IN THE FAULT CODE DIAGRAMS, D RING AT DOOR 2L DROPS BEHIND SLIDE PACK DUE TO DAMAGED TRIM. REINSTALLED TRIM AND INSTALLED NEW HOOK AND LOOP ON D RING.