What was found
AFT UPPER L/H TAIL SECTION OF FUSELAGE HAS DENT/CREASE ON SURFAC E BETWEEN FR 72-FR73 STRGRS 6L-8L A3NB-05-3-6062 PER HAECO LCQ N R 9292189 GENERATED BY V901665 DURING C-2 HAECO LCQ TECHNICIAN V892069 AND QC LC-32 REPAIRED DE NT INSTALLING REPAIR DOUBLER L=1.5"X W=1.5" FR72-FR73 STR6 L-STR8L IAW SRM 53-00-11-300-042 REPAIR CATEGORY B. INSPECTION P ADD EMP:V892069 ER SRI53-00-11-205-052 TABLE 004 FROM TIME OF REPAIR EMBODIMENT 60000FC/120000FH. SUBSEQUENT INSPECTIONS TBD, METHOD TBD. APPROVED. PER SRM 53-00-11-300-042 INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT 60000FC OR 120000 FH SUBSEQUENT INSPECTIONS AND METHOD TBD. TOMC-APPROVAL FROM SC1ELBYC COMMENT QC REVIEWED QC REVIEWED RECORDS UPDATE ..JF T/A: 60,000 FC OR 120,000 FC ..JF