What was found
THE FLOOR PROXIMITY LT ON OFCR L/H AFT LOWER ATTACHMENT WAS CRAC KED, REF NON-ROUTINE NO.9491250, ORIGINATED BY EMP V905459. PERFOMRED BY EMP V905459, REPLACED THE FLOOR PROXIMITY LT ON OFC R L/H AFT LOWER ATTACHMENT, PERFORMED OPERATIONAL TEST OF EMERGE NCY LIGHT, THE RESULT WAS ''SATIS'' REF TO AMM 33-51-00-00E-320A-A & AMM 33-51-06-00A-720A-A REV.130 ADD EMP:V905459 IDT BY TA423