What was found
(B757-53-3-0524) DENT ON AFT CARGO FRAME UPPER FLANGE AT STA 144 0 BETWEEN STR 25L - 26L. REF ST-SAA NR 0088762 CHECKED LIMITS TO DENT ON AFT CARGO FRAME UPPER FLANGE AT STA 14 40 BETWEEN S25L AND S26L L=1.30 W=.80 D=.028 OUT OF LIMITS IAW B 757-3 SRM 53-00-07 AD1 FIG 101 PG 101 REPAIRED FRAME IAW ECRA 53 60-01551 PART 1 INTERIM REPAIR. INITIATED DIP TO ACCOMPLISH INSP ECTIONS IAW ECRA 5360-01551 PART 2 INSPECTION REQUIREMENTS. WORK ACCOMPLISHED. PLACED ON DIP PER ECRA 5360-01551, PLANNING TO CONTACT ENGINEERI NG AFTER 33000 BUT BEFORE 34000 CYCLES FOR INSPECTION REQUIREMEN TS