What was found
EA 5510-01843 R/H HORRZANTAL STA RIB STA 92.70 HAS CRACK AT NO.2 VERTICAL STIFFENER TRANSATION RADIUS AND CRACKED VERTICAL WEB. REF BY PEMCO NR 2759N577. REPAIRED RH HORIZ STAB STIFFENER #2 IAW SRM 55-10-09RPR4 FIG202 AND REPAIRED LOWER SKIN IAW B737-800 SRM 55-10-01 RPR11 FIG204. INSP REQUIREMENTS PER TABLE 204 WITH INSP THRESHOLD @56000 TOTAL DIP 55-DIP PLEASE INCLUDE THE FOLLOWING INFORMATION - REFERENCE IS "TABLE 204" AND INCLUDE THE REPEAT INSPECTIONS REQUIRED FOR THE LIMITATIONS IN THE CORRECTIVE ACTION. REPAIRED RH HORIZ STAB STIFFENER #2 IAW SRM 55-10-09RPR4 FIG202 AND REPAIRED LOWER SKIN IAW B737-800 SRM 55-10-01 RPR11 FIG204. INSP REQUIREMENTS PER TABLE 204 WITH INSP THRESHOLD @56000 TOTAL CYCLES WITH REPEAT INSPECTION OF EXT DVI AT 9000FC AND LFEC AT 90000 CYCLES PER 737 NDT PART 6 51-00-26