What was found
REF AMES NR 0128 PANEL 447AR CHAFED(M) PANEL 447AR DEEPEST DEPTH WAS .025" EXCEEDED MAXIMUM LIMITS THE METAL WAS VERIFIED. FABRICATED AND TREATED, PRIMED AND APPLIED TOP COAT, IAW B767 54-53-70 DETAIL V ALLOWABLE DAMAGE, PL313T1200, DWG 313T1200, AMM 51-21-04, AMM 51-24-21, AMM 51-24-22. TOOL TAG 2721. SEE PARTIAL WORK ACCOMPLISHED AND PARTIAL WORKSHEET PG 1 ADD EMP: V928736.