What was found
STRINGER 41R BETWEEN FRAMES 61 AND 63 IS CORRODED. CORRODED STRINGER REMOVED AND NEW SPLICED IN PER SRM 53-00-13-300-001 FIG 1 SHEET 2. PER SRI 53-00-13-205-001 TABLE 006 NEED TO ACCOMPLISH INSPECTION AT 60,000 CYCLES OR 120,000 HOURS WHICHEVER IS ACHIEVED FIRST FROM REPAIR EMBODIMENT. WORK ACCOMPLISHED DURING HMV 3 IN LCQ ON NR 9296754. CREATING DIP FOR REINSPECTION REQUIREMENT. SUBSEQUENT INSPECTIONS TBD. OR 120,000 HOURS WHICHEVER IS ACHIEVED FIRST FROM REPAIR EMBODIMENT. DIP APPROVED PER SRM 53-00-13-300-001 NSPECTION AT 60,000 CYCLES TOMC-APPROVAL FROM SC1ELBYC COMMENT INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE. TOMC APPROVED : QC REVIEWED TOMC APPROVED : QC REVIEWED