What was found
PDA 3 LEFT WING #3 FLAP CANOE FAIRING O/B SIDE SEAL MISSING AND 3 FASTENERS PULLED THRU. ADDED PHOTO REMOVED AND REPLACED SEAL AND INSTALLED PER SRM 57-53-70 RPR 2 ALTERNATIVE 1. REF PARA 2 FOR DIP TO ACP DV INSP EVERY 500 FLT CYCLES TO ENSURE NO FURTHER DAMAGE TO HOLE SIZE. CURRENTLY UNDER THE ALLOWED .325" AS STATED IN ABOVE REF. PER SRM 57-53-70 RPR 2 ALTERNATIVE 1. REF PARA 2 FOR DIP TO ACP DV INSP EVERY 500 FLT CYCLES TO ENSURE NO FURTHER DAMAGE TO HOLE SIZE. IF FURTHER DMG IS FOUND REPAIR INTERIM REPAIR WITH PERMANENT REPAIR. TOMC-APPROVAL FROM SC1ELBYC COMMENT QC QC REVIEWED. RECORD UPDATE......CM RIR: 500 FC....CM U372988