What was found
3 RED LIGHTS ON LANDING GEAR EXTENSION ITEM LOCKED DUE TO RESULTANT MISSED APPROACH UNLOCKED FOR UPDATE, CONFIRMED THREE RED AND THREE GREEN, REDS EXTINGUISHED AFTER CYCLING HANDLE PER INBD CREW BOTH 3 RED AND 3 GREEN LANDING GEAR LIGHTS WERE ON PERFORMED FULL GEAR SWING PER AMM 32-32-00-710-801. OPS CHECK GOOD, COULD NOT DUPLICATE FAULTS. ADD EMP:U302625,U341130,U242104