What was found
PACK R ADVISORY PACK IS FAILED OR MANUALLY SHUT DOWN. FIM TASK REF : 21-50-F2-E0A-421A-A CMC MSG# 2164143 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CLIMB NARRATIVE: 21 CACTCS OPS CMC MSG# 2164143 NARRATIVE: SYNOPTICS FOR CURRENT STATUS UPON ARRIVAL. RELOCKED AFTER UPDATE. OK TO UNLOCK FOR UPDATE AFTER RDC REPLACEMENT. REPLACED REMOTE DATA CONCENTRATOR #17 AT DOOR 4L, LOADED RAN RH PACK ON THE RQ AND THE R2 CAC''S AND LEAKED CHECKED THE SOFTWARE SMX47-5560-6717 IAW AMM 42-21-07-07A-720A, STATUS MSGS PACKS NO LEAKS NOTED CLEAR. ADD EMP:196360 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1065745 SN OFF 7134 UNIT, REMOTE DA OFF 78-4240-9-9001 7134 ON 78-4240-9-9001 1471 REF LOG 7329733 FOR BLEED LOP WIRING CHECKS AS FOR FIM TASK 21-50-F2-47A-421A. FAULTS HAVE BEEN CLEARED AND NO FURTHER MX ACTION REQUIRED. REF LOG 7341470 FOR FAULT CONFIRMATION FLIGHT.PER LP 7341470,7347208 TEST FLIGHT GOOD.