What was found
SPLIT FLAPS ON CLIMBOUT L AT 2+ R AT 5. INLIMITS. FSEU BITE NOW NO EXSISTING FAULTS. OPERATED FLAPS SEVERAL TIMES NO FAULTS. PERFORMED FSEU BITE 27-51 TASK 801 EXSISTING FAULT : FLAP 3 SKEW INSPECTING FLAP 3 SKEW SENSOR FOUND CONNECTOR D11818 ON SENSOR 27-53252 HISTORY: LEG 00 FLAP 3 SKEW 27-53252 LEG -001 FLAP 3 LOOSE PERFORMED PIN CHECK AND CONNECTOR INSP. NO DAMAGE, SKEW 27-53252 INTERMITTANT. CONNECTED FLAP NEEDLES THEN PAIRED AND PERFORMED AMM 27-59-00-730-801 FLAP SKEW FUNCTION TEST ALL PARAMETERS NOTE DURING FLAPS IN SKEW CONDITION FSEU MOVES FLAP POSITION IND. NEEDLE REF. SDS 27-59-00-003. FLAPS OPS NORMAL WITH NORMAL IND. .