What was found
RIGHT ELEVATOR HAS A PUNCTURE FROM HAIL 8 1/2 INCHES OUT FROM INBOARD END AND 16 INCHES FROM TRAILING EDGE DIAMETER ABOUT .75 REF SRM 55-20-01-1A-1 FIGURE 102 , NO DELAMINATION NOTED OUTSIDE DAMAGE, SEALED WITH SPEED TAPE REVIEWED, LOCKED FOR MAINTENANCE FERRY UNLOCKED TO CLEAR LOGPAGE PERFORMED BY EMP V923294, RII BY EMP V903313,RH ELEVATOR A PUNCTURE REPAIRED AS PER SRM 55-20-01-2R-1 REPAIR 1 TABLE 202 PARA 4E AND SRM 51-70-04-2R-2 REPAIR 2 REV.87.