What was found
FOUND DENT IN FUSELAGE 2FT AFT OF L1 DOOR APPROX STATION 399 STRINGER S16 DENT APPROX DIMENSIONS 2IN WIDE 3IN HIGH AND 1/8IN DEEP. DENT MEASURSES 1.9 X 2.7 IN WITH DEPTH OF 0.120". LOCATED 6.5 IN REQUESTING QC DO A SKIN THICKNESS INSPECTION AT BLENDED AREA OF AS REQUESTED PERFORMED THICKNESS MEASUREMENT OF BLENDED AREA REF AFT OF STA 395 AT STRINGER 16L. BLENDED SCRATCHES. DENT . 757 NDT PART 4-51-00-01. LOWEST RECORDED THICKNESS OF .056". VERIFIED INSURANCE CUT PER SRM 53-00-01-2R-28 4 F. ALSO CONFIRMED ORIGINAL THICKNESS MEASUREMENT OF 0.062". REMOVED DAMAGE SKIN PER SRM 53-00-01-2R-28 REPAIR 28 PARA 4 PERFORMED HFEC OF CUTOUT AND HOLES FROM REMOVED FASTENERS PER PERFORMED INSPECTION OF DAMAGE REMOVAL PER SRM 53-00-01-2R-28 PERFORMED INSURANCE CUT PER SRM 53-00-01-2R-28 REPAIR 26 PARA 4 STEPA THRU D NDT PT 6 51-00-19, AND 51-00-16 TO SATISFY 4 E AND G OF SRM REPAIR 28 PARA 4 STEPA THRU D. OK TO CONTINUE. STEP F AND VERFIED ORGINAL SKIN AS .062" WITH MIC 53-00-01-2R-28. NO CRACK INDICATIONS OBSERVED. RII CW ON STEPS I THRU O, AND VERIFIED WASHERS, OK TO INSTALL REPAIR. VERIFIED REPAIR -3 FILLER AS .063 2024-T3 CLAD PO 8598582 AND -1 MATERIAL VERIFICATION CW PER ABOVE, OK TO FABRICATE. PER SRM 53-00-01-2R-28 REPAIR 28 PERFORMED PARA 4 STEPS I THRU DOUBLER AS .071 2024-T3 CLAD PO 7217276345 PER SRM O INSTALLED REPAIR WASHER WERE NEEDED PER PARA 4 STEP P(1) O.K. 53-00-01-2R-28. TO INSTALL ALL REPAIR PARTS COMPLETED HFEC INSP OF CUTOUT AREA IAW 757 NDT PT6 51-00-19 . VERIF