AD2019-11-02 EA 5310-06900 OP 031 REV D BS 1035 RH UNDERWING LONGERON 1EA CRACK FOUND AT CENTER TANK FRONT SPAR CHORD LAYER REF HX NR WO 816165, ORIG BY V914372 PREVIOUS ENTRY HAS A TYPO, SHOULD READ EA 5310-06900 OP 014 REV D EA 5310-06900 REV D OP 014 BS 1035 RH UNDERWING LONGERON AT CENTER TANK FRONT SPAR LOWER CHORD REPAIRED AS PER EC/RA 5710-02803 REV- PART 1 INTERIM REPAIR, REPEAT INSPECTION REQUIREMENT AS PER EC/RA 5710-02803 REV- PART 2. RII INSPECTED BY HX199407.