What was found
RT GEN OFF AFTER TAKE OFF. REMOVED AND REPLACED RIGHT ENG GCU, AFTER IDG REPLACED. ONLINE POWERING BUSSES. BPCU BITE TEST PASSED WITH NO FAULTS ALL THREE FEEDERS CHECK GOOD .4 OHMS TO GROUND. CHECKED ALL CT''S RECORDED AT THIS TIME. REF TASK 24-22-00-745-051-001. MENTIONED IN FIM, ALL CT''S READ GOOD. FIM MENTIONS TO REPLACE > ROTABLE PARTS CHANGE WAS INDICATED - TT # 1803107 SN OFF 0157 ADD FAULT: 24-35002 CONTROL, GENERA OFF 64-2422-9-0001 0157 ON 64-2422-9-0001 0109 PERFORMED OPS CHECK OF #2 IDG REF MM 24-11-00-715-016-001 . OPS CHECK GOOD NO FAULTS NOTED AT THIS TIME