What was found
AFT OF FR34 STR1R, 1EA ADDITIONAL FASTENER FOUND BETWEEN 2EA PRODUCTION FASTENERS WITH DAMAGE TO INTERNAL STR. REF SRI 53-21-13-300-018 TABLE 001. CURRENT PTT 34577FC/88004FH. INITIATE DIP TO ACCOMPLISH HFEC INSP THRESHOLD FROM TIME OF ADL/ RPR EMBODIMENT 48000FC/96000FH @ INTERVALS OF 5000FC/10000FH.... REPAIRED STR1R AFT OF FR34 IAW SRM 53-21-13-205-018. THIS IS A INSP THRESHOLD ABOVE SHOULD READ "FROM TIME OF ADL/RPR EMBOD CAT "B" RPR THAT WILL REQUIRE REINSPECTION. BY LHT TECH 5H0157 40000FC/80000FH". ALL OTHER ENTERED INTERVALS ARE ENTERED & INSP 5T1111. SEE ELB LP 3323081 FOR SKIN REPAIR. CORRECTLY.