What was found
CABIN FRAME IS CRACKED AT I/B FASTENER FOR PSU BRACKET STA.1120 BETWEEN S-8LT & S-9LT. [MARKED AND VERIFIED WITH HFEC] INSPECTION REQUIREMENTS AS GIVEN IN TABLE 203/REPAIR 8 ZONE 1. INSTALLATION, OR 50,000 AIRFRAME FLIGHT CYCLES, WHICHEVER COMES FLIGHT CYCLES. REFERENCE: MPD INSPECTION INTERVALS. NR# 1343117. INSPECTION THRESHOLD: 37,500 FLIGHT CYCLES FROM REPAIR FIRST. METHOD: GENERAL VISUAL INSPECTION. INTERVAL: 12,000 CUT OUT DAMAGE AND INSTALLED REPAIR PARTS WITH HEX DRIVE BOLTS. INSPECTION REQUIREMENTS: STEP 5 TABLE 203/REPAIR 8. DO THE