What was found
TWO AREAS OF CORROSION FOUND ON THE RH WING LOWER WINGTIP PANEL BETWEEN WBL 616.75 TO 658.17 WHILE AT GYR C-CHECK. BOTH LOCATION S WERE BLENDED AND ONE LOCATION REQUIRED A CUTOUT AND DOUBLER RE INFORCEMENT. THE REPAIR IS CONSIDERED AN INTERIM REPAIR AND REQU IRES A PERMANENT REPAIR. ACCOMPLISH A PERMANENT REPAIR PER PART 3 OF ECRA 5721-01477 LATEST REVISION ON OR BEFORE 18 MONTHS FROM JUN 16 2023. JUNE 16, 2023." CARRYING DIP TO ACCOMPLISH A PERMANENT REPAIR PER PART 3 OF EC/RA 5721-01477 (LATEST REVISION) ON OR BEFORE 18 MONTHS FROM TOMC APPROVES DIP, TWO AREAS OF CORROSION FOUND ON THE RH WING TOMC-APPROVAL FROM SC1ELBYC COMMENT LOWER WINGTIP PANEL BETWEEN WBL 616.75 TO 658.17 BOTH LOCATIONS WERE BLENDED AND ONE LOCATION REQUIRED A CUTOUT AND DOUBLER REINFORCEMENT. THE REPAIR IS CONSIDERED AN INTERIM REPAIR AND REQUIRES A PERMANENT REPAIR. ACCOMPLISH A PERMANENT REPAIR PER PART 3 OF EC/RA 5721-01477 ON OR BEFORE 18 MONTHS FROM 06/16/23 APPROVED. QC REVIEWED RECORDS UPDATE QC REVIEWED T/A: 18 MONTHS FROM 16JUN23 ...VC/U392424