What was found
CUTOUT DAMAGE AND REPAIR FUSELAGE FRAME AT STA 1580 BETWEEN S8R A ND S9R REF SRM 53-00-07 REPAIR 8 5 TABLE 203/REPAIR 8. DO THE INSPECTION REQUIREMENTS AS GIVEN IN TABLE 203/ CUTOUT DAMAGE AND REPAIRED FUSELAGE FRAME AT STA 1580 BETWEEN S8 R AND S9R REF SRM 53-00-07 REPAIR 8.INSPECTION REQUIREMENT STEP ADD EMP:V921314 DURING C-CK FRAME DAMAGE AT STATION 1580 BETWEEN STR 8R-9R WAS TOMC-APPROVAL FROM SC1ELBYC COMMENT REPAIRED PER SRM 53-00-07-2R-8 RPR 8. THIS IS CLASSIFIED AS CAT. B REPAIR AND FAA APPROVED PROVIDED SUPPLEMEMENTAL INSPECTIONS ARE COMPLETED. ZONE 3 INSPECTIONS ARE REQUIRED PER TABLE 203 12000 FC FROM REPAIR OR 50000 TAFC WHICHEVER COMES FIRST (12000 CYCLES FROM RPR). TOTAL AIRFRAME CYCLES CURRENTLY 19037. REPAIRS8. ZONE 3 INSPECTION THRESHOLD 12,00 FLIGHT CYCLES FROM R REVIEWED EPAIR INSTALLATION OR 50,000 AIRFRAME FLIGHT CYCLES WHICHEVER CO MES FIRST METHOD OF INSPECTION DETAIL VISUAL INSPECTION INTERVAL 12,000 FLIGHT CYCLES. RECORDS UPDATE -- DC QC REVIEWED RIR : 12000 FC --DCU391596