What was found
ELECTRICAL CONNECTORS IN THE MAIN WHEEL WELL DETAIL INSPECTION {B737-24-4-3085} - #2 ENG HYD SHUTOFF VALVE FAILS TEST. SLAVED IN NEW VALVE NO LUCK. DOES NOT MOVE TO OPEN POSTION WITH FIRE HANDLE UP UNMATED AND REMATED CANNON PLUG #S D46120, D40486, D46042 FOR UNMATED CANNON PLUG #S D43046 , D40400, D0764 FOR FOUND WIRE W6530-0508-20 IS INCORRECTLY INSTALLED IN PIN 3 OF TROUBLSHOOTING PURPOSES PER WM #29-11-11. OPS CHKS REQUIRED ON TROUBLESHOOTING PURPOSES PER WM #29-11-11. SUSPECT BAD WIRE RUN D40400J. SHOULD BE INSTALLED IN PIN 2 OF D40400J. W6530-1101-22 THESE. BETWEEN #D43046P AND #D40400J. IS INSTALLED IN PIN 2 AND SHOULD BE INSTALLED IN PIN 3 OF D40400J.