What was found
PANEL CAME DOWN AT 33 DEF REDO 1 PIN OR REPLACEMENT OF MODULE PER WDM 35-21-14. HANDED OVER TO OPPOSITE CREW. PRELIMINARY INSPECTIONS OF 33DEF FOUND OXY MASK DEPLOYMENT WIRING FOR MODULE M00064 WITH WIRE BUNDLE W1170 AND WIRES121-20R AND W1170-122-20G OF CANNON PLUG D2996 WITH ONE WIRE PULLED OUT OF PIN AND ONE WIRE SHEARED. IT REQUIRES A SPLICE REPAIR AND ADD EMP:U381930 DOOR LATCH ACTUATOR REPLACED AS PER AMM 35-21-15 PB 401 AND WDM 35-21-14-1 PAGE 1. OPS CHECK PERFORMED AS PER 35-21-00-705-054. VERIFIED OXYGEN GENERATOR HOSES CONNECTED CORRECTLY AND SAFETY PIN IS REMOVED AT 33DEF.