Service difficulty report · Selector Valve · Boeing 757224

Difficulty date
July 30, 2024
Submitted
August 2, 2024
Operation
Air carrier
Aircraft
N12114
Make and model
Boeing 757224
Aircraft serial
27556
Aircraft time
112,918 hours, 23,442 cycles
Part
Selector Valve
Part number
4034010013
Part serial
0713
Condition
Faulted
Location
Lt Mlg
Part time
112,911 hours, 23,439 cycles
Stage of operation
NR
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT HYD QTY LT ON /AT .45 TURNED L ENG/ELEC OFF FAILED. HYD LEAKS FROM SAME LOCATION BETWEEN UNION AND SELECTOR VALVE. SUSPECT FAULTY SELECTOR VALVE. ACFT ARRIVED WITH .14 HYD QTY NO PUMPS ON. REMOVED LT HYD SYS PRESSURE IAW AMM 29-11-00. R & R UNION & PACKING (LR)(6) IAW AMM 32-31-02. PRESSURIZED L HYD SYS PER AMM 29-11-00. SERVICED L HYD SYS PER AMM 12-12-01. PERFORMED LEAK CHECK OF SELECTOR VALVE. LEAK CHECK, R & R LT LANDING GEAR SELECTOR VALVE IN RT WHEEL WELL, OPS CHECK GOOD LEAK CHECK GOOD REF AMM 32-31-02 40-0595-3-1983.