What was found
EMERGENCY LIGHTS OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - RIGHT AFT EMERGENCY EIXT LOWER LIGHT INOP ROW 21 FOUND RIGHT AFT EMERGENCY EXIT DOOR LIGHT L1188 CONNECTED TO WIRING FOR AFT OVERWING DOOR FWD TRIM HEATER M2202. SWAPPED CONNECTION, R/R DAMAGED EMERGENCY EXIT SIGN IAW AMM 33-51-01. OPS CHECK FOR EMERGENCY EXIT LIGHT GOOD IAW AMM 33-51-00. OPS CHECK FOR RIGHT AFT OVERWING EXIT DOOR HEAT GOOD IAW AMM 21-45-00. PARTS USED: 29-3351-3-0022,QTY :1