Service difficulty report · Electrical Box · Boeing 7879

Difficulty date
February 1, 2025
Submitted
February 5, 2025
Operation
Air carrier
Aircraft
N26966
Make and model
Boeing 7879
Aircraft serial
60143
Aircraft time
40,694 hours, 3,941 cycles
Part
Electrical Box
Part number
RDFA313401
Condition
Faulted
Location
Seat 12d
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

12D MONITOR INOP. NEEDS FURTHER TROUBLESHOOTINGPAC CONFIRMED FAULT SEAT 12D MONITOR INOP, ACP GVI OF CONNECTORS AT SEATBOX AND SPM IAW AMM 44-25-00, NFF. RAR SEB IAW AMM 44-25 -03, AND ATTEMPTED OPS CHECK, DURING BOOT UP, STRONG ODOR EMITTE D FROM SEAT, UPON FURTHER T/S FOUND CONNECTOR J20 BURNT, WILL REQUIRE REPLACEMENT OF HARNESSES P/N RD-FM6393-001 & RD-FP1374-2 605. HARNESS RD-FM6393-001 NIS @ORD AT THE MOMENT TO ACP RAR. RE F DRAWING IS61527_B B787-9 SHEET 22. RECOMEND REPLACING SEATBOX AGAIN ONCE HARNESSES ARE REPLACED P/N RD-FA3134-01. REMOVED FOOTREST PANELS AT 12D FOR WIRING HARNESS ACCESS. REMOVED AND REPLACED IN-SEAT HARNESSES FROM THE ECO-SEB TO THE J10/J20 DISCONNECTS AND FROM THE P1/J20 DISCONNECT TO SEAT 12D PERIFERALS. PARTS OFF AND ON RD-FP1374-2605, RD-FP0713-9140. AFTER POWER UP SEAT BOX WOULD NOT READDRESS. REQ FURTHER T/S. 2IFR277D SECOND HARNESS REMOVED AND REPLACED WAS RD-FP0713-914B. NOT 9140. REPLACED ECO-SEB AT 11D IAW AMM 44-25-03. WOULD NOT READDRESS. REQ FURTHER T/S. PERFORMED VOLTAGE CHECK AT MONITOR CONNECTOR AT 12D, FOUND NO PO WER GOING TO MONITOR. CHECKED VOLTAGE AT J3 CONNECTOR ON DC-SEB ON PINS 1,2 & 6,7 FOUND EXCESSIVE REPLACED HARNESS FROM J4 ON THE SPM TO J7A OUTLET DISCONNECT AND J7B OUTLET DISCONNECT IAW IS61527. OPS CHECK NORMAL FOR OUTLETS IAW AMM 44-25-00.

More about the Boeing 787-9