What was found
FOUND ACR BUNK 6 PSU CONNECTOR MOUNT DAMAGED, WHILE CARRYING OUT PASSENGER OXYGEN BOTTLE INITIATOR GVI. ACR BUNK 6 PSU ASSY REPLACED FOUND SATIS IAW AMM 35-21-00, AIRCRAFT. UPDATED RFID DETAILS UPLOADED THROUGH IPAD 35-21-04 INSTALLATION TEST C/OUT FOUND SATISFACTORY IAW SUCCESFULLY. AMM 35-21-04PRIOR, NEW RFID TAG INSTALLED ON OXY CYLINDER, RFID SCANNING C/OUT ON ABOVE MENTIONED OXY BOTTLE.